AUTHORS
Aida Al-Qasmi 1 , Waffa Al-Alawi 1 , Azharuddin Mohammed Malik 2 , Rashid Manzoor Khan 1 , Naresh Kaul 1 , *
Dec 08, 2016 This video was created for the training of MCG residents in setting up the STORZ C-MAC videolaryngoscope.
AUTHORS INFORMATION
1 Department of Anesthesia and ICU, Khoula Hospital, Oman Medical Specialty Board, Muscat, Sultanate of Oman
2 Department of Medicine, J N Medical College and Hospital, Aligarh University, Aligarh, India
* Corresponding author: Naresh Kaul, Department of Anesthesia and ICU, Khoula Hospital, Muscat, Sultanate of Oman. Tel: +96-824571690, Fax: +96-824571690, E-mail: [email protected]
ARTICLE INFORMATION
READ FULL TEXT
Abstract
Background: Tracheal intubation using Storz’s C-Mac D-bladeTM videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade.
The V-PRO maX Sterilizer just got more productive. The 28 minute Non Lumen Cycle can now process loads up to 50 lbs including cameras, batteries, cables, non-lumened endoscopes and similar devices. STERIS continues to raise the bar on device processing and strives to makes sterile processing departments more productive, consistent and dependable resulting in maximum performance while ensuring a high standard of patient care.
How V-PRO maX Low Temperature Sterilization System Works
The V-PRO maX sterilizer, our most exciting product yet, is designed with three sterilization cycles to efficiently sterilize a variety of instrument types, using our proprietary vaporized hydrogen peroxide technology. The Flexible Cycle enables you to sterilize single or dual channel surgical flexible endoscopes with or without an additional load in 35 minutes!
NVMS-7000 is a video management software using a distributed structure to provide centralized management for all the. This user manual describes the function, configuration and operation steps of NVMS-7000 software. To ensure the. And the information of the device such as the MAC. Nvms7000 mac manual. User Manual (F1) Click to open the User Manual; you can also open the User Manual by pressing F1 on your keyboard. About View the basic information of the client software. Language Select the language for the client software and reboot the software to activate the settings. The NVMS7000 client software is composed of the following function modules.
Why V-PRO maX Low Temperature Sterilization System?
- Flexibility- Process mixed loads such as two Surgical Flexible Scopes (or) one Surgical Flexible Scope and non-lumen loads up to 24 pounds.
- Productivity- Process more than 4 times the weight capacity and up to two times more Lumen devices* per load than STERRAD 100NX. Processing options include a 35-minute Flexible Cycle, a 55-minute Lumen Cycle and a 28-minute Non Lumen Cycle.
- Efficiency - The lack of a plasma coil allows for more usable room in the chamber. Low sensitivity to moisture minimizes aborted cycles, saving time and money, and enabling faster device turnaround.
- Safety -
- Employees: V-PRO Sterilizers are safe for healthcare employees and the environment. Click here to read about V-PRO Sterilizer Environmental H2O2 Safety Testing.
- Patients: No toxic residuals remain on devices.
- Environment: No harmful byproducts.
Electronic Record Management with ConnectAssure™ Technology
Seamlessly connect and get immediate results from your V-PRO maX Low Temperature Sterilizer, and Celerity HP BI Incubator with ConnectAssure Technology. Whether data is sent to your facility's tracking system or the ConnectAssure application, your cycle information including BI results are available with the click of a mouse for essential compliance reporting.
User Manual Example
*As of August 17, 2016, STERRAD 100NX and NX Sterilizers are cleared by the FDA to process 10 stainless steel lumens per load. Additionally, loads up to 10.7 lbs can be processed in the Express Cycle of the STERRAD 100NX; V-PRO maX Sterilizer is cleared to process 20 stainless steel lumens per load and up to 50 lbs in the Non Lumen Cycle.